Miele-Logo
da2900
DA 2900Enlarge image
 
DA 2900

Installation

Ceiling blower
For installation in a ceiling
110 cm wide

Operating mode

Extraction mode
Recirculation mode possible with optional accessories (Recirculationbox DUU 2900)

Controls

Touch controls with LED lights for hob lighting, ON/OFF and power control
Operating hours counter for grease and charcoal filters (individually programmable), Run-on time (5/15 min)
The Intensive setting can be programmed to switch off automatically after 10 minutes
Three fan settings plus Intensive
Operating of the appliance possible with remote control (accessory supplied)

Features

Four removable dishwasher-safe stainless steel grease filters
Dishwasher-safe edge extraction panels in glass or stainless steel available as additional accessories
CleanCover for simple cleaning of canopy interior
LED hob lighting, 4 x 2 watt
Electronic suction power regulation
Double-sided radial fan
DC motor for maximum energy saving
Power management system
Non-return flap
Ducting diameter 150/125 mm
Recommended ducting diameter: 150 mm
Extraction is possible to the top or the sides in any direction
Sound insulation inside cooker hood

Safety

Safety switch-off

Extraction rate

Extraction 150 mm Ø by EN 61591
Int. 620 m³/h, 66 dB(A) re 1 pW (52 dB(A) re 20 µPa Sound pressure)
Max. 390 m³/h, 54 dB(A) re 1 pW (39 dB(A) re 20 µPa Sound Pressure)
Extraction 125 mm Ø by EN 61591
Int. 590 m³/h, 67 dB(A) re 1 pW (53 dB(A) re 20 µPa Sound Pressure)
Max. 350 m³/h, 55 dB(A) re 1 pW (40 dB(A) re 20 µPa Sound Pressure)
Recirculation 150 mm Ø by EN 61591
Int. 510 m³/h, 70 dB(A) re 1 pW (55 dB(A) re 20 µPa Sound Pressure)
Max. 290 m³/h, 62 dB(A) re 1 pW (47 dB(A) re 20 µPa Sound Pressure)

Standard accessories

Remote control
Reducing stub for 125 mm Ø

Optional accessories

Recirculationbox DUU 2900
Communication module XKM 2000 DA for Con@ctivity
Silencer DASD 150
Wall pipe DMK 150
Roof fitting kit DDF 125/150
Flexible ducting DAS 150

Important

Also available as a production special

Product availability, information and prices are subject to change without prior notice.

Installation drawings

These installation diagrams should be used as a planning guide only and must be read in conjunction with the operating and/or installation instructions.
1. Suction side
2. Fan, ducts upwards or to any side
3. Motor can be installed to suit. Ducting and connection cable
required to link to
appliance
4. Min. gap of 50 mm required for installation against a wall